We independently review everything we recommend. When you buy through our links, we may earn a commission. Learn more›

How to Change Capacitor on Air Compressor: Guide

How to change capacitor on air compressor safely, identify the correct replacement, and avoid common wiring mistakes. Updated for November 2026.

BOJACK Run Capacitor 60 uF 300V AC 60 MFD CBB60 2 Wire 50/60Hz Cylinder Motor Run Capacitor for Motor Blower air Compressor and air Conditioner Compressor Replacement Part
Ages 18-24? Explore Prime for Young Adults and see if you are eligible

A compressor motor that hums, struggles to start, or stops unexpectedly can point to an electrical problem, but a capacitor is only one possible cause. Learning how to change capacitor on air compressor starts with confirming the part type and ratings, then making the equipment safe before opening its electrical cover. Capacitors can retain a dangerous charge after power is disconnected, so this repair deserves more care than a routine filter change.

The products listed below include replacement run capacitors, a motor start capacitor, a compressor-specific DeWalt replacement part, and a capacitor guard. Their ratings and intended uses differ, so matching the original part matters more than choosing by appearance. For related compressor maintenance context, see our guide to air compressor nozzle replacement and our article on safe compressor pressure practices.

Product Shortcode

Award Product ACR Score About ACR ScoreThe ACR Score is our own rating from 0 to 10, based on performance, design and build, ease of use, and value. It reflects independent research and is never influenced by manufacturers, retailers, or affiliate commissions. Learn more ›
Best Overall BOJACK Run Capacitor 60 uF 300V AC 60 MFD CBB60 2 BOJACK Run Capacitor 60 uF 300V AC 60 MFD CBB60 2 9.2/10 Buy
Best Budget Air Compressor Capacitor Guard Steel Insulation Air Compressor Capacitor Guard Steel Insulation 9.1/10 Buy
BOJACK Run Capacitor 16 uF 250V AC 16 MFD CBB60 2 BOJACK Run Capacitor 16 uF 250V AC 16 MFD CBB60 2 9.1/10 Buy
Best Value CD60 350uF 350MFD Motor Start Capacitor for Heat CD60 350uF 350MFD Motor Start Capacitor for Heat 8.9/10 Buy
CBB60 Run Capacitor, Wire 250VAC 120uF 50/60Hz CBB60 Run Capacitor, Wire 250VAC 120uF 50/60Hz 8.8/10 Buy
Best Premium DeWalt 5140235-65 Run Capacitor Replacement Part DeWalt 5140235-65 Run Capacitor Replacement Part 8.8/10 Buy
BOJACK Run Capacitor 120 uF 250V AC 120 MFD CBB60 BOJACK Run Capacitor 120 uF 250V AC 120 MFD CBB60 8.6/10 Buy
BOJACK Run Capacitor 80 uF 300V AC 80 MFD CBB60 2 BOJACK Run Capacitor 80 uF 300V AC 80 MFD CBB60 2 8.4/10 Buy
2PC SPP6 Hard Start Capacitor Increases Compressor 2PC SPP6 Hard Start Capacitor Increases Compressor 8.0/10 Buy
1
BOJACK Run Capacitor 60 uF 300V AC 60 MFD CBB60 2
Best Overall

BOJACK Run Capacitor 60 uF 300V AC 60 MFD CBB60 2

BOJACK · 9.2/10 ACR Score About ACR ScoreThe ACR Score is our own rating from 0 to 10, based on performance, design and build, ease of use, and value. It reflects independent research and is never influenced by manufacturers, retailers, or affiliate commissions. Learn more ›

2
Air Compressor Capacitor Guard Steel Insulation
Best Budget

Air Compressor Capacitor Guard Steel Insulation

Housoutil · 9.1/10 ACR Score About ACR ScoreThe ACR Score is our own rating from 0 to 10, based on performance, design and build, ease of use, and value. It reflects independent research and is never influenced by manufacturers, retailers, or affiliate commissions. Learn more ›

3
BOJACK Run Capacitor 16 uF 250V AC 16 MFD CBB60 2

BOJACK Run Capacitor 16 uF 250V AC 16 MFD CBB60 2

BOJACK · 9.1/10 ACR Score About ACR ScoreThe ACR Score is our own rating from 0 to 10, based on performance, design and build, ease of use, and value. It reflects independent research and is never influenced by manufacturers, retailers, or affiliate commissions. Learn more ›

4
CD60 350uF 350MFD Motor Start Capacitor for Heat
Best Value

CD60 350uF 350MFD Motor Start Capacitor for Heat

BLARYETI · 8.9/10 ACR Score About ACR ScoreThe ACR Score is our own rating from 0 to 10, based on performance, design and build, ease of use, and value. It reflects independent research and is never influenced by manufacturers, retailers, or affiliate commissions. Learn more ›

5
CBB60 Run Capacitor, Wire 250VAC 120uF 50/60Hz

CBB60 Run Capacitor, Wire 250VAC 120uF 50/60Hz

YWBL-WH · 8.8/10 ACR Score About ACR ScoreThe ACR Score is our own rating from 0 to 10, based on performance, design and build, ease of use, and value. It reflects independent research and is never influenced by manufacturers, retailers, or affiliate commissions. Learn more ›

6
DeWalt 5140235-65 Run Capacitor Replacement Part
Best Premium

DeWalt 5140235-65 Run Capacitor Replacement Part

DEWALT · 8.8/10 ACR Score About ACR ScoreThe ACR Score is our own rating from 0 to 10, based on performance, design and build, ease of use, and value. It reflects independent research and is never influenced by manufacturers, retailers, or affiliate commissions. Learn more ›

7
BOJACK Run Capacitor 120 uF 250V AC 120 MFD CBB60

BOJACK Run Capacitor 120 uF 250V AC 120 MFD CBB60

BOJACK · 8.6/10 ACR Score About ACR ScoreThe ACR Score is our own rating from 0 to 10, based on performance, design and build, ease of use, and value. It reflects independent research and is never influenced by manufacturers, retailers, or affiliate commissions. Learn more ›

8
BOJACK Run Capacitor 80 uF 300V AC 80 MFD CBB60 2

BOJACK Run Capacitor 80 uF 300V AC 80 MFD CBB60 2

BOJACK · 8.4/10 ACR Score About ACR ScoreThe ACR Score is our own rating from 0 to 10, based on performance, design and build, ease of use, and value. It reflects independent research and is never influenced by manufacturers, retailers, or affiliate commissions. Learn more ›

9
2PC SPP6 Hard Start Capacitor Increases Compressor

2PC SPP6 Hard Start Capacitor Increases Compressor

YESHINDA · 8.0/10 ACR Score About ACR ScoreThe ACR Score is our own rating from 0 to 10, based on performance, design and build, ease of use, and value. It reflects independent research and is never influenced by manufacturers, retailers, or affiliate commissions. Learn more ›

Replacing an Air Compressor Capacitor Safely and Correctly

Replacing a compressor capacitor is a part-matching and electrical-safety task, not a universal wiring procedure. First confirm that the capacitor is actually faulty and identify whether the motor uses a start capacitor or a run capacitor. Then isolate the compressor from power, discharge stored electrical energy using the manufacturer-approved method, document the original connections, and install a compatible replacement. If the wiring, discharge method, or capacitor identity is uncertain, stop and have a qualified service professional handle the repair.

Know what the capacitor does before opening the housing

An electric motor capacitor helps establish the electrical conditions needed for motor operation. A start capacitor generally provides temporary assistance during startup, while a run capacitor is designed to remain in the motor circuit during operation. Those roles are different, and the parts are not automatically interchangeable just because their cases or wire leads look alike. The compressor’s wiring diagram and original component markings are the strongest references for identifying which type is installed.

Symptoms can suggest a motor or capacitor problem, but they do not prove the capacitor has failed. A motor that hums or fails to start may also have a mechanical obstruction, a supply issue, a failed switch, damaged wiring, or another motor fault. A compressor that trips a breaker can have several possible causes as well, and repeatedly resetting the breaker without diagnosis can create additional risk. Disconnect the unit and consult its service information instead of treating every startup problem as a capacitor replacement.

Some compressors use more than one capacitor, and some replacement parts are specific to a particular motor or compressor model. Check whether the part is marked start or run, then compare its capacitance, voltage rating, frequency, terminal arrangement, dimensions where relevant, and part number with the original and manufacturer documentation. A physical match alone is not enough. If the compressor label or service diagram specifies a replacement part, follow that information rather than estimating a rating.

Match capacitance, voltage, and capacitor function

Capacitance is commonly shown in microfarads, written as uF or MFD. The replacement should match the original capacitance within the tolerance allowed by the compressor or motor manufacturer. The voltage rating also matters: it must be suitable for the application and must not be lower than the specified original rating. A higher voltage marking by itself does not establish that a capacitor is compatible, because capacitance, type, terminal layout, physical fit, and circuit role still need to agree.

The supplied product listings illustrate why checking every marking matters. BOJACK lists CBB60 run capacitors in 16 uF, 60 uF, 80 uF, and 120 uF versions, with the 16 uF unit rated at 250V AC and the 60 uF and 80 uF units rated at 300V AC. Another listing describes a 120 uF CBB60 run capacitor rated at 250V AC. Those different values are not a menu of interchangeable choices; use only the specification that matches the compressor’s original part and service requirements.

Start capacitors require the same careful identification. The listed CD60 component is described as a 350 uF motor start capacitor, while the CBB60 listings identify run capacitors. Do not substitute a run capacitor for a start capacitor, or the reverse, based only on wire count or a similar cylindrical shape. The product description for the DeWalt 5140235-65 identifies it as a run capacitor replacement for the DXCM301, so that model-specific listing should not be treated as evidence of compatibility with other DeWalt compressors.

Make the compressor safe before electrical service

Switch the compressor off and disconnect it from its power source before removing an electrical cover. For a hardwired unit, use the manufacturer’s isolation instructions and do not work on conductors that may still be energized. Unplugging or isolating power does not necessarily remove charge stored in a capacitor. Follow the service manual’s capacitor discharge procedure and use suitable, properly rated equipment; do not improvise a discharge method with a screwdriver or other metal object.

Stored air pressure is a separate hazard from electrical charge. Depressurize the tank completely before servicing or moving the compressor, following the compressor manufacturer’s instructions, and keep clear of pressurized fittings. Do not open the tank, alter its pressure switch, or defeat its safety relief device as part of a capacitor repair. Wear suitable eye protection, keep the work area dry, and avoid proceeding if the unit has damaged wiring, a burned connector, or signs of overheating that you cannot safely assess.

Do not assume that a visibly intact capacitor is safe to touch or that a swollen case is the only sign of failure. Capacitors can retain charge even when the motor has been off for some time. If the manual does not explain how the component is to be discharged and verified, or you do not have the electrical training and equipment to follow the procedure, leave the repair to a qualified technician. That is especially important for equipment connected to a fixed supply or with unclear wiring.

Document the original wiring before disconnecting anything

Once the unit is safely isolated and the capacitor has been discharged and verified according to its service instructions, access the capacitor compartment as the manual directs. Photograph the original wiring clearly before removing a connector, and label wires if the service documentation permits that approach. Record which terminal each lead occupies rather than relying on memory or wire color alone. Manufacturers may use different diagrams and terminal markings, so the actual compressor documentation takes priority.

Inspect the component and nearby wiring for loose terminals, corrosion, melted insulation, or heat damage. A damaged connector can cause poor contact and recurring trouble even after a capacitor is replaced. Do not bend, cut, or splice conductors simply to make a replacement reach. If terminals or insulation are compromised, or the wiring does not match the diagram, stop and arrange proper repair before restoring power.

Remove and install the replacement without changing the circuit

After confirming that the original part is discharged, remove its connectors by gripping the connector body rather than pulling on the wire. Avoid damaging the terminal or stretching the lead. Compare the replacement markings and terminals with the original and the manufacturer’s specified part information before installation. If the replacement’s capacitance, voltage, type, or connection arrangement does not match the requirements, do not install it.

Connect the wires to the corresponding terminals shown in the compressor’s wiring diagram and in your pre-removal record. Capacitor terminals may be marked differently between designs, and a two-wire part does not make polarity or circuit placement irrelevant. Do not guess which wire goes where, bridge terminals, or modify the motor circuit to accommodate an uncertain part. If the diagram is missing or the labels cannot be read, obtain the correct documentation or professional service rather than experimenting.

Secure the capacitor in its intended holder and reinstall any cover or guard that protects it from contact and environmental exposure. The supplied Housoutil listing describes a steel capacitor guard intended as a protective enclosure, but its product description does not establish compatibility with every compressor. Confirm the guard’s fit and installation requirements for the specific unit. Keep the capacitor and wiring protected as designed, and do not leave the electrical compartment open during operation.

Restore power only after a careful visual check

Before reconnecting power, verify that the capacitor is secured, each connector is seated on the intended terminal, no tool or loose hardware remains in the compartment, and all required covers are back in place. Compare the finished wiring with the manufacturer’s diagram, not just a photograph. If anything differs from the documented arrangement, keep the compressor disconnected until the discrepancy is resolved. Never bypass a fuse, pressure switch, thermal protector, or other safety component to make the motor run.

Follow the manufacturer’s instructions for returning the compressor to service. Observe the startup from a safe position and listen for abnormal humming, repeated starting attempts, smoke, unusual odor, or a breaker trip. Turn the unit off and isolate power immediately if it behaves abnormally; do not keep cycling it to see whether the symptom clears. A successful start is useful evidence, but it does not certify that the capacitor circuit or the rest of the compressor is free of defects.

If the compressor starts normally, let it operate only as directed by its manual and check for signs of unusual heating or electrical odor without touching exposed parts. Confirm that its normal controls and protective devices remain in place and that the tank operates within its stated limits. Do not adjust factory pressure-switch settings as part of this repair. If the motor still struggles, trips protection, or stops during operation, further diagnosis is needed instead of another speculative capacitor swap.

What to do when a new capacitor does not solve the symptom

A replacement that matches the markings but fails to resolve the problem points toward another part of the system or a fault that needs proper electrical diagnosis. Possible areas include the supply connection, motor, switch, wiring, or a mechanical condition that prevents the pump from turning freely. The available product data does not provide a diagnostic test for those faults, so avoid inferring a specific cause from one symptom alone. Have a qualified service person test the unit if the cause is not clear.

Repeated breaker trips deserve particular caution. A capacitor with the wrong specification, a damaged motor, a wiring fault, or a supply problem may all contribute, but the correct explanation depends on the compressor and electrical installation. Do not replace a properly rated breaker with a larger one, defeat a thermal overload, or use an unsuitable extension cord to keep the compressor running. Follow the compressor’s electrical requirements and have the circuit assessed when the supply may be involved.

A persistent hum after replacement is not a reason to tap the motor or repeatedly switch it on and off. Disconnect power and check only what the manufacturer identifies as safe for the owner to inspect. Internal motor testing, live measurements, and wiring changes are better left to someone qualified to perform them. This conservative approach helps prevent an uncertain repair from turning into a damaged motor or an electrical injury.

Choose the right replacement from the listed options

For a replacement purchase, compare the original capacitor’s complete label with the product specification, including whether it is a start or run type, its capacitance, AC voltage rating, frequency, tolerance where specified, and lead or terminal arrangement. The BOJACK and YWBL-WH listings describe CBB60 run capacitors for motor applications, while the BLARYETI listing describes a CD60 start capacitor. These product descriptions help distinguish categories, but they do not establish that any given value fits a particular compressor.

The DeWalt part is the most specifically identified compressor replacement in the supplied data because the listing names the DXCM301. Verify the compressor model and the part number against its service documentation before ordering. The description also cautions buyers to verify the part number, which is appropriate for any model-specific component. If a listing does not identify your exact compressor or motor, contact the seller or manufacturer with the model and original capacitor markings before buying.

The hard-start kit in the product listings is described for air-conditioning compressor applications, not as a general substitute for an air compressor motor capacitor. Similar terms such as compressor capacitor can refer to parts used in different equipment and circuits. Do not install an air-conditioning hard-start device on a shop compressor unless the compressor manufacturer explicitly specifies that part for the model. A product’s broad application wording is not a substitute for a circuit diagram or confirmed compatibility.

Once a correct replacement is installed, retain the old part’s identification details and the compressor model information for future reference, but do not keep or reuse a failed capacitor. If another failure occurs, look for an underlying electrical or mechanical cause instead of repeatedly replacing the component. The practical endpoint is not simply a motor that turns once; it is a correctly specified part, secure documented connections, intact protective covers, and normal operation under the manufacturer’s instructions.

In short, identify the capacitor type and ratings from the compressor itself, isolate electrical power and stored air safely, and follow the model-specific wiring and discharge instructions. If any part of those steps is unclear, professional service is the safer choice. A correctly matched capacitor may address the fault, but it cannot correct unrelated wiring, motor, supply, or mechanical problems.

About the author

Tony Carrick
Tony Carrick

Tony Carrick is an experienced product researcher and writer specializing in tools, home improvement, automotive maintenance, and consumer equipment. With extensive experience reviewing tools and tackling hands-on renovation projects, he brings a buyer-focused perspective to compressor performance, usability, and overall value.